Endurance:
| 6 hrs
|
Ceiling:
| 7.6 km
|
Payload:
| >2700 kg
|
Research Speed:
| 100-150 m/s
|
Aircraft Instrument Package for the NOAA/NCAR Lockheed Electra
Parameter
|
Time Resolution
|
Method
|
Det. Limit
|
Ozone (O3) |
10 s |
UV Absorption |
1 ppb |
Fast O3 (FO3) |
1 s |
NO/O3 Chemiluminescence |
0.2 ppb |
Fast CO (FCO) |
1 s |
VUV Resonance Fluorescence |
1 ppb |
Carbon Dioxide (CO2) |
< 1 s |
NDIR |
0.2 ppm |
Sulfur Dioxide (SO2) |
2 s |
UV Pulsed Fluorescence |
1 ppb |
Nitric Oxide (NO) |
1 s |
NO/O3 Chemiluminescence |
30 ppt |
Nitrogen Dioxide (NO2) |
3 s |
Photolysis, NO/O3 Chem. |
100 ppt |
Total Nitrogen Oxides (NOy) |
1 s |
Au Converter, NO/O3 Chem. |
50 ppt |
PAN |
1 s / every 6 min |
Dir. Injection, GC/ECD |
< 5 ppt |
PPN |
1 s / every 6 min |
Dir. Injection, GC/ECD |
< 5 ppt |
MPAN |
1 s /every 6 min |
Dir. Injection, GC/ECD |
< 5 ppt |
Nitric Acid (HNO3) |
1 s |
C I Mass Spectrometry |
10 ppt |
NH3 |
5 s |
C I Mass Spectrometry |
50 ppt |
In-situ VOCs |
1 min./every 15 min |
Cryo Collection, GC/FID |
< 10 ppt |
Canister VOCs |
< 1 min. |
Canister Sampling, GC/MS |
< 10 ppt |
CH2O |
|
Liquid Chromatography |
|
Peroxides (incl. H2O2) |
1 min |
Dual Enzymatic / Fluorimeter |
30 ppt |
Aerosol size distribution |
1 s |
NMASS |
5 - 90 nm |
Aerosol size distribution |
1 s |
ERAST |
70 - 1000 nm |
Total Radiation |
1 s |
Eppley Pyranometers - Zenith & Nadir |
0.28 - 2.8 µ |
UV Radiation |
~10 s |
Spectral Radiometer - Zenith & Nadir |
295 - 480 nm |
Visible Radiation |
|
Visible Absorption Spectrometer |
420 - 700 nm |
Water Vapor (H2O) |
1 s |
Lyman Alpha Absorption |
|
Air Temperature |
1 s |
Platinum Thermistor |
|
Dewpoint/Frostpoint |
< 3 s |
Chilled Mirror |
|
Wind Speed |
1 s |
Derived from INE |
|
Wind Direction |
1 s |
Derived from INE |
|
Altitude |
1 s |
Barometric |
|
Position |
1 s |
GPS, INE |
|
Air Speed |
1 s |
Barometric |
|
Biometer |
|
3-wavelength IR Absorption |
|
Atmospheric Reflectivity |
|
C & X Band Radars |
|
[Back to Top]
|
|